< HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN"> Individually Crafted Fire Resistant Door Sets | Fire Resistant Door Set - Longden Doors Graphics versionTEXT VERSIONADD TO FAVOURITESCONTACT US

HOMEABOUT USCONTACT USLITERATURENEWS


THE LONGDEN APPROACHINTERIOR DOOR STYLES

Overview »

The Moderne Collection

└ Overview »

└ Door Designs »

└ Design Options »

└ Technical »

Panelled doors

└ Panelled doors »

└ Flat Panel Doors
- Sheraton »

└ Raised & Fielded Doors
- Chippendale »

└ Door Components »

└ Applied Mouldings »

└ Panel Beads »

Boarded doors »

Glazed doors

└ Glazed doors »

└ Glazed door styles »

Other door styles »

Joinery details »EXCLUSIVE HOTELSEXCLUSIVE HOMESCONSERVATION & HERITAGECOMMERCIALSPECIFICATION

Overview »

NBS specification guides »HARDWOODSARCHITECTURAL HARDWARE

Overview »

Architectural Key »

Lever Handles »

Knob Furniture »

Flush Bolts & Locks »

External Furniture »

Accessories »

Handings »

Care of Finishes »JOINERY

Frames »

Other joinery items »GLAZINGFINISHESPERFORMANCE
CHARACTERISTICS

Use of doorsets »

Terminology »

Configurations & handings »

Tolerances & dimensions »

Hardwoods »

Fire resistance »

Sound reduction »ACCESSORIESCARE FOR TIMBER DOORSCOMPANY POLICIES

Quality »

Health & safety »

Timber purchasing policy »

Environmental policy »

Forest Stewardship Council »

CIS »HISTORYCASE STUDIESDOORSET GALLERYCONTACT

General »

Location & map »

Longden »

 
home » performance characteristics: fire resistance » Building Regulations Approved Document Part B, ‘Fire safety’, identifies situations where fire resistant doors and door sets – described as ‘fire doors’ are needed, as well as the restriction of smoke leakage. It also specifies the level of protection (30 or 60 minutes) and refers to appropriate test standards. Part B firmly recognises the relevance of UKAS accredited, independent product conformity certification schemes to ensure that fire resistance performance levels are actually achieved on-site. Independent initiatives, such as the CERTIFIRE scheme, are designed to ensure that installed fire doors perform as intended and members are subjected to rigorous and comprehensive appraisal. CERTIFIRE audits are usually undertaken by the ISO 9000 Inspectorate during manufacture and only CERTIFIRE approved glazing and seals are used.

Building Regulations concentrate on protecting occupants but there is also protection of the building itself to consider, particularly with historic properties. Fire resistant doors and door sets offer the most effective means of containing fire and smoke, so protecting historic building fabric without the damaging effects of sprinklers.

The Longden range of fire resistant door sets can achieve up to FD60 (60- minutes) fire rating, with smoke control where needed, fully certified and supported by the BWF-CERTIFIRE scheme. Longden has passed its CERTIFIRE audit test with further door set testing carried out enabling larger doors, panels and areas of glazing to be certified as fire resistant.

Panelled

Boarded

Rivelin

Sheraton

Chippendale/Copeland

 

 

Fire performance to BS 476 Part 22

Non Rated

FD30

FD60

Non Rated

FD30

FD60

Non Rated

FD30

Non Rated

FD30

Suitable for internal use Suitable for external use Thickness

45-58mm

45-58mm

58mm

45-58mm

45-58mm

58mm

45mm

45mm

45mm

45mm

Smoke controlSound reduction

Standard Seals

30RwdB

30RwdB

30RwdB

30RwdB

30RwdB

30RwdB30RwdB*

30RwdB*

Acoustic Seals

38RwdB

37RwdB38RwdB

37RwdB35RwdB*

35RwdB*

* Note: Based on glass performance.